GPU systems and cooling for AI and HPC

Specify. Source. Supply.

We source data centre GPU systems, and the cooling that lets them run at density, for organisations building AI and high performance computing capacity. Both are supplied against one clear written quote.

Explore cooling

An unbranded open frame server rack holding stacked 2U servers, with neatly dressed cables, in a bright, quiet room

02

A GPU server with its lid removed on a pale inspection bench

Our mission

Our purpose is to help organisations get the GPU systems they have specified: from reputable sources, with clear paperwork at every step, and delivered with care to the site that will run them.

Cooling now sits alongside GPU systems, because dense systems need both planned together. We start there because that is where the pressure is. As the company grows we will extend the same approach to servers, storage and networking, one category at a time.

03

Why cooling matters now

Dense GPU racks give off more heat than many rooms were built to remove. The cooling choice therefore affects which systems you can run, where you can put them, and how many fit in a rack.

Scoping the cooling with the GPU systems, rather than after them, avoids a system that arrives and cannot be switched on at full load.

New build or existing room?

Some approaches suit an existing room with standard racks, such as rear door heat exchangers and liquid-to-air units. Others, such as direct-to-chip with facility water, need facility water or a new layout. We ask about your site first.

04

What we supply

GPU systems

  • 01
    An unbranded multi GPU server, lid removed

    GPU servers

    Multi GPU servers for training and inference, configured to your specification.

    SuppliedView category
  • 02
    An integrated GPU rack with its front door open

    Rack scale GPU systems

    Integrated racks for larger clusters, scoped with you and your site.

    SuppliedView category
  • 03
    Two unbranded data centre GPU cards on a plain surface

    PCIe GPUs and workstations

    Data centre and workstation GPUs for existing servers and development teams.

    SuppliedView category

Not sure which GPU platform fits? The GPU selector compares NVIDIA platforms side by side from datasheet figures and suggests a configuration you can send to us for a written quote.

Open the GPU selector

Cooling

  • 04

    Direct-to-chip liquid cooling

    Cold plates on the GPUs and CPUs, manifolds in the rack, heat carried away in liquid.

    SuppliedView approach
  • 05

    Coolant distribution units (CDUs)

    Separate the server loop from the facility loop and control flow, temperature and filtration.

    SuppliedView approach
  • 06

    Rear door heat exchangers

    A coil in the rack's rear door removes heat as air leaves. Fits standard racks.

    SuppliedView approach

Coming later

  • 07

    Servers

    General purpose rack servers to sit alongside GPU systems.

    PlannedView category
  • 08

    Storage

    NVMe and capacity storage for training data and checkpoints.

    PlannedView category
  • 09

    Networking

    Switching, adapters, optics and cabling for clusters.

    PlannedView category

Images are illustrative and do not show specific products.

Need colocation space too?

We can help you find space for your GPU systems and plan it with the systems and cooling we supply.

A locked black mesh cage door in a white wall, with server racks visible behind it

Planning GPUs and cooling together?

Tell us the systems, the site and the timeline, and we will come back with one written quote that covers both.

06

What a combined quote can cover

Every quote is written for your project.
ItemBasis
GPU servers or rack scale systemsIncluded in the quote when you ask for it
Cooling at the chip: cold plates and manifoldsIncluded in the quote when you ask for it
Coolant distribution unitIncluded in the quote when you ask for it
Rear door heat exchangerIncluded in the quote when you ask for it
Delivery and paperworkIncluded in the quote when you ask for it
  • ClearWritten quotes, plain terms.
  • CarefulChecks before every supply.
07

How we work

Five services, in the order they happen.

  1. 01

    Scoping

    We confirm workload, configuration, quantity and site constraints before anything else.

  2. 02

    Configuration and validation

    We check the bill of materials, power, cooling and interconnect fit before quoting, and check the system against the cooling and power you have or plan.

  3. 03

    Sourcing

    We source the configuration and confirm details in the written quote.

  4. 04

    Compliance and checks

    Sanctions, export control, end use and know your customer checks before any quote is final.

  5. 05

    Logistics and delivery

    We arrange delivery to your site and confirm the terms in writing.

From enquiry to written quote

RefStepWhat happensWhat we need from you
HND-01Enquiry receivedLogged and given a reference such as ENQ-2026-0001.Configuration, quantity, timeline, contact details.
HND-02ScreeningBuyer, owners and end use checked against sanctions and export control lists.Organisation details, end use country, end user if different.
HND-03Technical reviewConfiguration reviewed, with questions if needed.Replies to any questions. A bill of materials or part numbers help.
HND-04Written quoteIf we can help, a written quote with its own terms.Read the quote and its terms.
HND-05OrderOn written acceptance of a quote only.Written acceptance under the quote terms.

No contract is formed until a written quote is accepted under terms we will provide.

08

Tell us what you need

A few lines about your systems, site or timeline are enough to start.

GPUs

GPU systems

Data centre GPU systems, configured to your specification and quoted in writing, with the cooling to match scoped alongside. Servers, storage and networking will follow as separate categories.

01

Categories

  • 01
    An unbranded multi GPU server, lid removed

    GPU servers

    Multi GPU servers for training and inference, configured to your specification.

    SuppliedView category
  • 02
    An integrated GPU rack with its front door open

    Rack scale GPU systems

    Integrated racks for larger clusters, scoped with you and your site.

    SuppliedView category
  • 03
    Two unbranded data centre GPU cards on a plain surface

    PCIe GPUs and workstations

    Data centre and workstation GPUs for existing servers and development teams.

    SuppliedView category

Coming later

  • 04

    Servers

    General purpose rack servers to sit alongside GPU systems.

    PlannedView category
  • 05

    Storage

    NVMe and capacity storage for training data and checkpoints.

    PlannedView category
  • 06

    Networking

    Switching, adapters, optics and cabling for clusters.

    PlannedView category

Images are illustrative and do not show specific products.

02

Classes we quote for

RefClassTypical configurationOrder basis
SOS-01Multi GPU rack serversRack-mount node with four or eight GPUs, dual CPU, large memory, high speed fabricPer node or per rack
SOS-02Rack scale GPU systemsIntegrated racks of nodes with networking, scoped with your sitePer rack
SOS-03PCIe GPUs and workstationsData centre and workstation cards, single or multi card, with or without a hostPer card
SOS-04Memory, storage and interconnect for GPU systemsNode memory, NVMe storage, adapters, optics and cabling for the systems aboveWith a system or separately

Generic classes only. No models, vendors or prices are published.

03

Cooling to match

In general terms. The right answer depends on the configuration; we confirm it in the quote.

RefClassCooling to matchRead more
SOS-01Multi GPU rack serversAir cooled or liquid cooled, depending on the configuration. Dense nodes usually need liquid at the chip or at the rack door.Direct-to-chip, Rear door
SOS-02Rack scale GPU systemsUsually liquid cooled, with a CDU in the rack or the row. Depends on the configuration; we confirm this in the quote.CDUs, Direct-to-chip
SOS-03PCIe GPUs and workstationsUsually air cooled. Either, when installed in a dense server.Cooling hub
SOS-04Memory, storage and interconnectFollows the system it goes into.Cooling hub

Air cooled or liquid cooled?

Qualitative only. Both are valid; the site usually decides.

QuestionAir cooledLiquid cooled
What it needs from the roomEnough cold air supply and hot air return for the rack, and a room that can carry the heat away.A coolant loop: facility water, or a liquid-to-air unit where there is none. Pipework, a CDU and leak management.
Where it fitsExisting rooms, lower density racks, smaller deployments, edge sites.Dense GPU racks, new builds, rooms that already have water, rack scale systems.
What to ask usWhether the configuration you want is available air cooled, and what that means for rack count.Which approach suits your site, what the quote should include, and what the facility must provide.
04

Category detail

An unbranded multi GPU server, lid removed

GPU servers

Multi GPU servers are the building block of most AI and high performance computing deployments. We scope the GPU count, host CPU, memory, storage and interconnect with you, then source the configuration and quote it in writing.

Each quote states the full configuration, quantity, price, validity, and payment and delivery terms, so there is nothing to interpret later.

Key considerations

  • GPU count per node. Four or eight accelerators per chassis, and what that means for power and cooling.
  • Interconnect. Ethernet or fabric between nodes, and the switching to match.
  • Memory. Host memory per node, sized for the workload rather than the catalogue.
  • Power and cooling. Per rack draw and the facility's ability to remove the heat. See Cooling.
  • Rack space. Units per node, rail kits and the weight your floor can take.

Specifications

Provided with your quote.

Cannot find what you need? Request a quote.

Images are illustrative and do not show specific products.

05

Checks we carry out

Sanctions and export control

Before any quote is finalised, we screen the buyer, its owners and the end user against UK sanctions and export control lists. Where a licence is required, no order proceeds until it is in place.

Know your customer

On a first order we verify the buyer's identity, registration and beneficial ownership, and we may ask for supporting documents.

Payment

Payment terms are agreed with each order and set out in the quote.

End use and destination

A declaration of end use and destination country is required for every order. We may ask for an end user undertaking.

The same checks apply to cooling equipment and to combined quotes. A quote may be declined on compliance grounds, and we may decline or not respond to any enquiry.

Cooling

Cooling for dense GPU systems

Dense GPU racks give off more heat than air alone can comfortably remove. We supply the cooling equipment that goes with the systems we quote, so both arrive planned as one.

The back of a row of black server racks with coolant manifolds, paired hoses and overhead cooling pipework
01

From chip to room

Heat has to be removed somewhere. Each approach does it at a different point.

From chip to room: where heat is removedHeat moves from the chip, through the rack and the row, to the facility side. Cold plates take heat at the source; manifolds, in-rack CDUs and rear doors handle it at the rack; in-row and liquid-to-air CDUs handle it in the row; facility water, dry coolers and chillers reject it outside. At the chipAt the rackIn the rowFacility side Cold plates onGPUs and CPUsDirect-to-chip ManifoldsIn-rack CDURear doorheat exchanger In-row CDULiquid-to-air CDUPipework andcontainment Facility waterDry coolersChillers

In words: heat leaves the chip through cold plates (direct-to-chip); at the rack it passes through manifolds, an in-rack CDU or a rear door heat exchanger; in the row an in-row or liquid-to-air CDU hands it on; the facility side (facility water, dry coolers, chillers) takes it from there.

02

Cooling approaches

  • 01

    Direct-to-chip liquid cooling

    Cold plates on the hottest parts, with coolant carried through manifolds in the rack.

    • Dense GPU servers
    • New builds and rooms with water
    • Rack scale systems
    SuppliedView approach
  • 02

    Coolant distribution units

    Keep the facility loop and the server loop apart, and manage flow, temperature and filtration.

    • Any liquid cooled system
    • In-rack, in-row or liquid-to-air
    • Rooms with or without water
    SuppliedView approach
  • 03

    Rear door heat exchangers

    A coil replaces the rack's rear door and takes the heat out of the air as it leaves.

    • Existing rooms
    • Standard racks
    • Air cooled servers at higher density
    SuppliedView approach
03

Compare the approaches

ApproachWhere heat is removedNeeds facility waterFits an existing roomTypical use
Direct-to-chipAt the chip, through cold platesUsually, through a CDU. Liquid-to-air units can avoid itSometimes; depends on the siteDense GPU servers and rack scale systems
CDUBetween the server loop and the facility loopDepends on the unit typeUsually, in-row and liquid-to-air types in particularAny liquid cooled system
Rear door heat exchangerAt the rack, as air leavesUsually, or a separate chilled loopUsually; fits standard racksExisting rooms adding denser racks

Words such as usually and sometimes are deliberate. The answer depends on the site, and we confirm it in the quote.

04

What we need from you

  • Room or site type: existing room, new build or colocation space.
  • Rack count and layout.
  • Power available per rack, if known.
  • Whether facility water is available.
  • The GPU systems planned.
  • Timeline and delivery region.

We source cooling equipment from established manufacturers.

05

Cooling questions

C01What is direct-to-chip cooling?

Metal cold plates sit on the GPUs and CPUs. Coolant flows through them, picks up the heat and carries it out of the server through manifolds in the rack to a coolant distribution unit.

C02Do GPU servers need liquid cooling?

Not always. Many configurations are available air cooled. Denser nodes and rack scale systems are increasingly designed for liquid, and some are only offered that way. It depends on the configuration; we confirm this in the quote.

C03Can liquid cooling be added to an existing room?

Often, yes. Rear door heat exchangers fit standard racks, and liquid-to-air CDUs reject heat into the room without facility water. Direct-to-chip with facility water usually needs pipework and a plan for the room.

C04What does a CDU do?

A coolant distribution unit keeps the loop that runs through the servers separate from the facility loop, and controls flow, temperature and filtration. Units come as in-rack, in-row or liquid-to-air.

C05What is a rear door heat exchanger?

A coil that replaces the rack's rear door. Server fans push hot air over it, coolant in the coil takes the heat, and the air leaves at about room temperature. Passive versions rely on server fans; active versions add their own.

Cooling / Direct-to-chip liquid cooling

Direct-to-chip liquid cooling

Cold plates take heat straight from the GPUs and CPUs, so the hottest parts are cooled by liquid rather than air. It is the usual route for dense GPU servers and rack scale systems.

An open GPU server fitted with copper cold plates and black coolant tubing with quick disconnect couplings
01

How it works

  1. 01

    Cold plates

    Cold plates sit on the GPUs and CPUs in each server, in place of or alongside the usual heatsinks.

  2. 02

    Manifolds

    Coolant flows through hoses to manifolds in the rack, which feed and return each server.

  3. 03

    CDU

    A coolant distribution unit moves the heat on to facility water, or to room air in a liquid-to-air unit.

02

Where it fits

  • Dense GPU servers where air cooling is at its limit.
  • New builds and rooms that already have facility water.
  • Rack scale systems designed for liquid from the start.

03

Things to check

  • Facility water: available, or a liquid-to-air unit instead.
  • Rack and server compatibility with cold plates and manifolds.
  • Pipework routes, floor loading and leak detection.
  • Maintenance access to quick disconnects and manifolds.
  • Warranty position for liquid cooled configurations.

04

What we can supply

  • Liquid cooled GPU server configurations.
  • Cold plate kits where offered by the system manufacturer.
  • Rack manifolds, hoses and quick disconnects.
  • Coolant distribution units (see CDUs).

Specifications

Provided with your quote.

Datasheets

On request.

Images are illustrative and do not show specific products.

05

Related GPU systems

Multi GPU rack servers and rack scale GPU systems. See GPUs for the classes we quote for.

Back to the cooling hub

Quote direct-to-chip liquid cooling with your GPU systems

One written quote can cover the systems and the cooling. Tell us about the site and we will scope both.

Cooling / Coolant distribution units

Coolant distribution units

A CDU sits between the loop that runs through your servers and the loop the building provides. It keeps the two apart and controls what the servers see.

A coolant distribution unit with its door open, showing pumps, valves and a heat exchanger beside a server rack
01

How it works

  1. 01

    Two loops

    The facility loop and the server loop are separated by a heat exchanger inside the unit, so building water never enters the servers.

  2. 02

    Control

    Pumps, valves and sensors manage flow, temperature and filtration on the server side.

  3. 03

    Form factors

    Units come as in-rack, in-row, or liquid-to-air, which rejects heat into the room where there is no facility water.

02

Where it fits

  • Any direct-to-chip deployment.
  • Rooms with facility water (in-rack or in-row units).
  • Rooms without facility water (liquid-to-air units).

03

Things to check

  • Facility water: temperature, flow and quality available.
  • Space: a rack unit, a row position or floor space.
  • Redundancy: how many units and pumps the design needs.
  • Filtration, coolant specification and top up.
  • Monitoring and alarms, and who responds to them.

04

What we can supply

  • In-rack coolant distribution units.
  • In-row coolant distribution units.
  • Liquid-to-air coolant distribution units.
  • Associated manifolds, hoses and fittings.

Specifications

Provided with your quote.

Datasheets

On request.

Images are illustrative and do not show specific products.

05

Related GPU systems

Rack scale GPU systems and multi GPU rack servers specified for liquid cooling.

Back to the cooling hub

Quote coolant distribution units with your GPU systems

One written quote can cover the systems and the cooling. Tell us about the site and we will scope both.

Cooling / Rear door heat exchangers

Rear door heat exchangers

A rear door heat exchanger replaces the back door of a rack with a coil. Hot air from the servers passes through it and leaves close to room temperature. It is often the simplest way to raise density in an existing room.

The back of a server rack fitted with a rear door heat exchanger, its finned coil and coolant hoses visible
01

How it works

  1. 01

    Replace the door

    The rack's rear door is swapped for a door carrying a coil and coolant connections.

  2. 02

    Air over coil

    Server fans push hot exhaust air through the coil. Active versions add fans of their own.

  3. 03

    Air leaves cool

    The coolant takes the heat away; the air returns to the room at about room temperature.

02

Where it fits

  • Existing rooms with standard racks.
  • Air cooled servers running at higher density.
  • Sites that want to avoid changes inside the servers.

03

Things to check

  • Rack compatibility: door size, hinge and depth.
  • Coolant supply: facility water or a dedicated chilled loop.
  • Passive or active, and the power for active fans.
  • Floor loading with the extra weight of the door and water.
  • Maintenance access behind the rack.

04

What we can supply

  • Passive rear door heat exchangers.
  • Active (fan assisted) rear door heat exchangers.
  • Matching racks where needed.
  • Hoses, fittings and associated CDUs (see CDUs).

Specifications

Provided with your quote.

Datasheets

On request.

Images are illustrative and do not show specific products.

05

Related GPU systems

Multi GPU rack servers in air cooled configurations, and PCIe GPUs and workstations installed in dense servers.

Back to the cooling hub

Quote rear door heat exchangers with your GPU systems

One written quote can cover the systems and the cooling. Tell us about the site and we will scope both.

Where it goes: AI

AI

GPU systems for training, inference and private AI, scoped with the interconnect, memory and cooling each workload needs.

A short row of black GPU server racks fed by neat cabling from an overhead tray

01

A cold aisle between two rows of black server cabinets with perforated doors

AI training clusters

Training runs want many GPUs working as one. The hard part is rarely the GPU itself; it is the fabric between nodes, the memory per node, and whether the facility can power and cool a full rack.

We scope the cluster as a whole, from node configuration to switching and cabling, and quote it in writing with the site constraints written down.

What buyers usually need

  • GPU class: multi GPU rack servers or rack scale systems.
  • Interconnect: high speed fabric between nodes.
  • Memory: large host memory per node.
  • Storage: fast shared storage for data and checkpoints.

Cooling to consider

Dense training racks usually need liquid at the chip, with a CDU in the rack or row. Direct-to-chip, CDUs.

Related products

GPU servers, Rack scale GPU systems

02

A 2U rack server slid out on its rails from a black rack

Inference and edge

Serving models in production is a different shape of problem: smaller footprints, predictable latency and often many sites rather than one.

We help you size per site systems and quote repeatable configurations, so each location gets the same build.

What buyers usually need

  • GPU class: smaller GPU servers or PCIe GPUs in standard hosts.
  • Interconnect: standard Ethernet in most cases.
  • Memory: sized to the models served.
  • Storage: local, for models and logs.

Cooling to consider

Usually air cooled. A rear door heat exchanger can help where several nodes share a small room. Rear door heat exchangers.

Related products

GPU servers, PCIe GPUs and workstations

03

A small server rack in a tidy office comms room

Enterprise private AI

Some data cannot leave the building. Private AI capacity means GPU systems on your own premises, sized to the workload and fitted into an existing estate.

We scope against your current racks, network and security requirements, and quote systems that fit what you already run.

What buyers usually need

  • GPU class: GPU servers, sometimes a small rack scale system.
  • Interconnect: Ethernet, with fabric where several nodes train together.
  • Memory: matched to the models and fine tuning planned.
  • Storage: integrated with existing enterprise storage.

Cooling to consider

Existing comms rooms often favour rear door heat exchangers or liquid-to-air CDUs, because facility water is rare. Rear door heat exchangers, CDUs.

Related products

GPU servers, Rack scale GPU systems

Where it goes: HPC

HPC

GPU and CPU systems for research, engineering and simulation, and the data centres that host them, quoted with the cooling to run them at full load.

A row of closed racks in a quiet HPC machine room, with insulated cooling pipes overhead

01

A GPU workstation on a laboratory bench

Research and university labs

Labs buy against grants, timetables and shared facilities. The specification is usually clear; the constraints are budget, procurement rules and the room the system goes into.

We quote in writing against your procurement requirements and note anything about power, cooling or access that the facility will need to confirm.

What buyers usually need

  • GPU class: GPU servers or workstations, sometimes a shared cluster.
  • Interconnect: fabric for multi node jobs, Ethernet otherwise.
  • Memory: large host memory for simulation and analysis.
  • Storage: parallel or shared storage for datasets.

Cooling to consider

Shared facilities vary. Air cooled where the room allows; rear door or direct-to-chip where a cluster is planned. Rear door heat exchangers, Direct-to-chip.

Related products

GPU servers, PCIe GPUs and workstations

02

A tower workstation on a desk beside a precision machined metal part

Engineering and simulation

Modelling, analysis and design runs put steady, heavy load on both GPUs and CPUs for long periods, often on a schedule set by the project rather than the IT team.

We scope systems for sustained throughput, check them against the room they will live in, and quote them with the cooling they need.

What buyers usually need

  • GPU class: multi GPU rack servers, or workstations for individual engineers.
  • Interconnect: fabric for tightly coupled solvers.
  • Memory: large host memory and fast local storage.
  • Storage: capacity for results and revisions.

Cooling to consider

Sustained load means sustained heat. Direct-to-chip for clusters; rear door for a few dense racks in an existing room. Direct-to-chip, Rear door heat exchangers.

Related products

GPU servers, PCIe GPUs and workstations

03

A colocation data hall aisle lined with lockable black cabinets with mesh doors

Data centres and colocation

Rack scale supply into a colocation facility needs coordination with the operator: delivery windows, floor loading, power commissioning and remote hands.

We arrange delivery to the facility and confirm every term in writing, so the operator and your team work from the same document.

Need the space as well as the systems? Colocation.

What buyers usually need

  • GPU class: rack scale GPU systems or full racks of GPU servers.
  • Interconnect: fabric within the rack, uplinks to the facility network.
  • Memory and storage: as the workload requires.

Cooling to consider

Depends on what the facility offers: facility water for direct-to-chip, or rear door heat exchangers on a chilled loop. Direct-to-chip, CDUs, Rear door heat exchangers.

Related products

Rack scale GPU systems, GPU servers

Colocation

Colocation space, sourced with your systems

We help you find colocation space for your GPU systems and introduce you to the operator. If you need them, we can also supply the systems and cooling that go in it.

A colocation data hall aisle lined with lockable black cabinets with mesh doors
01

What we do

Finding space, buying GPU systems and planning cooling usually means talking to three different providers. We help with all three, starting from what you need.

  1. 01

    Colocation space

    We look for space that fits your power, cooling and timeline, and introduce you to the operator.

  2. 02

    Systems to match

    GPU systems, servers and cooling, sourced for the space you take.

  3. 03

    You contract directly

    You agree the space and its terms with the operator directly. We introduce you and do not hold the operator contract.

02

An empty colocation cage of black steel mesh with its door open, around four closed black server racks

How we approach it

We are vendor agnostic and client led. We start from what you need, not from a stock list.

We look for space with a rate and lead time that suit you, then introduce you to the operator.

Colocation only, or space and GPU systems together: both are welcome. When you also take GPU systems from us, we can plan delivery, power and cooling around the space you choose.

03

Where we work

We currently focus on mainland UK and Europe.

A low rise data centre building with rooftop cooling plant, set in landscaped grounds on an overcast day

04

An empty open frame rack with vertical power strips and neatly dressed green power cables, ready for installation

What to tell us

  • Power needed, in kW per rack or in total.
  • Number of racks, or the GPU systems you plan to run.
  • Preferred country or region.
  • Contract length you have in mind.
  • Cooling: air, liquid, or not sure.
  • When you need the space.
  • Whether you also need GPU systems or cooling from us.

Every enquiry gets a reference. The colocation contract is agreed directly between you and the operator.

05

Next steps

  1. 01

    Tell us the requirement

    Send the power, racks, region and timeline you have in mind.

  2. 02

    We shortlist options

    We look for space that fits, talk the options through with you and introduce you to the operator.

  3. 03

    You agree terms with the operator

    You contract with the operator directly. Any GPU systems or cooling from us are quoted separately in writing.

A black rack server on a steel lift trolley beside an empty rack, with sealed boxes ready for installation

Prefer email? sales@duvaracompute.com

How we work

From enquiry to written quote

Five steps, whether the request is for GPU systems, cooling, or both. Each enquiry carries a reference from receipt, and nothing is agreed until a written quote is accepted.

01

Five services

  1. 01

    Scoping

    We confirm workload, configuration, quantity and site constraints before anything else.

  2. 02

    Configuration and validation

    We check the bill of materials, power, cooling and interconnect fit before quoting, and check the system against the cooling and power you have or plan.

  3. 03

    Sourcing

    We source the configuration and confirm details in the written quote.

  4. 04

    Compliance and checks

    Sanctions, export control, end use and know your customer checks before any quote is final.

  5. 05

    Logistics and delivery

    We arrange delivery to your site and confirm the terms in writing.

02

The five steps

RefStepWhat happensWhat we need from you
HND-01Enquiry receivedLogged and given a reference such as ENQ-2026-0001.Configuration, quantity, timeline, contact details.
HND-02ScreeningBuyer, owners and end use checked against sanctions and export control lists.Organisation details, end use country, end user if different.
HND-03Technical reviewConfiguration reviewed, with questions if needed.Replies to any questions. A bill of materials or part numbers help.
HND-04Written quoteIf we can help, a written quote with its own terms.Read the quote and its terms.
HND-05OrderOn written acceptance of a quote only.Written acceptance under the quote terms.
03

What happens at each step

HND-01

Your enquiry is logged and given a reference such as ENQ-2026-0001. Quote it in any correspondence, or if you wish to withdraw the enquiry.

HND-02

We screen the buyer, its owners and the stated end user before technical work starts. We may ask for registration details or an end use declaration at this point.

HND-03

We review the configuration against what we can source and may come back with questions, for example on interconnect, memory per node, facility water or delivery region.

HND-04

If we can help, we send a written quote with its own terms: configuration, quantity, price, validity, payment and delivery terms.

HND-05

An order is placed only by written acceptance of a quote under its terms. No contract is formed until a written quote is accepted under terms we will provide.

About

About Duvara Compute

A UK business that sources and supplies data centre GPU systems, and the cooling to run them, to organisations building AI and HPC capacity, against a written quote.

A tidy workbench with a sealed shipping box, cable and tools, ready for a delivery

01

Our mission

Organisations building AI and high performance computing capacity need GPU systems that match what they specified, arrive when agreed, and come with paperwork that stands up to scrutiny. That is harder than it sounds in a market where demand runs ahead of supply and detail gets lost between buyer, supplier and site.

Duvara Compute exists to close that gap. We confirm the requirement, check it against power, cooling and interconnect, source it from reputable channels, carry out the compliance checks that a careful supplier should, and put the whole thing in a written quote before anyone commits. We start with GPU systems and the cooling that lets them run at density, because dense systems need both planned together. Servers, storage and networking will follow, built on the same habits.

02

What sets us apart

Written quotes, plain terms
Everything that matters is on paper before an order exists.
Checks before supply
Sanctions, export control, end use and know your customer checks come first.
Honest about what we can source
If we cannot get it, or cannot get it when you need it, we say so.

03

How we work together

Listen first
We understand the workload and the site before we talk about hardware.
Be precise
Part numbers, quantities and dates are written down and checked.
Keep promises small, and keep them
We commit only to what we can control, then do it.
Respect and fairness
Towards buyers, suppliers, carriers and colleagues alike.
Integrity
We follow the rules that apply to this trade, even when nobody is checking.

04

Company facts

Name
Duvara Compute Ltd
Company number
17543239
Registered in
England and Wales
Incorporated
26 October 2026

Questions

Questions

Q01Who can enquire?

Businesses, resellers and integrators, public sector bodies, and research or education organisations. We do not take enquiries from consumers.

Q02What should I include in a quote request?

Your name, work email, company and a short message are enough to start. For a quote, add the platform or system class, quantity range, interconnect, memory per node, timeline, delivery region and end use country under Add project details. Part numbers help.

Q03Can I send a bill of materials or part list?

Yes. Paste it into the Message field. For longer lists, send the form first, then email the file to sales@duvaracompute.com quoting your reference.

Q04Do you publish prices?

No. We do not publish prices or stock. If we can help, we respond to a request with a written quote.

Q05What does a quote include?

A written quote states the configuration, quantity, price, how long the quote is valid, and payment and delivery terms.

Q06Is a quote request binding?

No. An enquiry is not an order or an offer. No contract is formed until a written quote is accepted under terms we will provide.

Q07Do you supply hardware other than GPUs?

Yes. Alongside GPU systems we now supply cooling equipment for GPU deployments: direct-to-chip kits, coolant distribution units and rear door heat exchangers. Servers, storage and networking are planned as later categories, and we will say so on the GPUs page when they are available. See Cooling.

Q08How do you screen buyers?

We screen the buyer, its owners and the end user against UK sanctions and export control lists before any quote is finalised, and carry out know your customer checks on a first order. A declaration of end use and destination country is required.

Q09What happens to my data?

We use the details you give to respond to your request and keep a record of it. We do not sell data and set no cookies. See the Privacy notice.

Q10Can I enquire as a public body?

Yes. Choose "Public sector" as the buyer type under Add project details, and note any procurement requirements in your message.

Q11How do I withdraw a request?

Email sales@duvaracompute.com quoting your enquiry reference. We will close it and delete the record on request.

Q12Will you reply to every request?

We review each one. If we can help, we send a written quote. We may contact you for more detail first, and we may decline or not respond to any enquiry.

Q13Who are you?

Duvara Compute Ltd, a company registered in England and Wales, company number 17543239. Full company details are in the footer of every page.

Q14Can you quote GPU systems and cooling together?

Yes. That is the point of offering both. Choose "GPU systems and cooling" on the contact form, tell us about the site, and one written quote covers the systems and the cooling equipment. See Cooling.

Contact

Contact us

Ask a question or request a quote for GPU systems, cooling, or both. We reply to enquiries as soon as we can.

A few lines is fine. For a quote, add the configuration, quantities or part numbers. 10 to 4000 characters.
Add project details (optional)

Everything here is optional. It helps us prepare a quote faster.

About you
Include the country code.
As registered, if you have one.
System
Nodes or cards.
When you need a quote.
Cooling
If known, for example the kW per rack you are planning for.
Delivery and end use
Where the equipment will be used.
If different from the buyer.

An enquiry is not an order or an offer. A reference such as ENQ-2026-0001 is issued on receipt.

Read the Privacy notice and Terms of enquiry.

For longer part lists, email the bill of materials to sales@duvaracompute.com after you send the form, quoting your reference.

Thank you. We have received your message.

We will contact you if we can help.

Enquiry reference ENQ-2026-0001 ReceivedOn receipt StatusLogged, awaiting screening

An enquiry is not an order or an offer. No contract is formed until a written quote is accepted under terms we will provide.

Please keep this reference for your records. We reply to enquiries as soon as we can.

Questions about this message, or want to withdraw it? Email sales@duvaracompute.com quoting this reference.

Back to home